。The contactor has install current –limited resistor, can restrain the switch on inrush current .
。The contactor is direct-acting and double-break structure, operation flexible, conveniently manual operation inspect.
。The contactor connection terminal has insulating boot , very safe.
。The contactor can be install by screw, also can install in the bus bar.
CJ19 Switch-Over Capacitor Contactor
General Description:
ZHIYUE brand of CJ16(19) Switch-over capacitor contactor is new type of components for electric appliances,which is developed and produced on the basis of the introduced foreign technology of the same kind , The device is widely applied to the low voltage reactive power compensation screen to replace the subassembly composed of three Xd1 current-limiting reactors and a CJ10 cotnactor, and it is also can be used in the general control circuit to limit flashy flow.
Characteristics:
1.The contactor has install current –limited resistor, can restrain the switch on inrush current .
2.The contactor is direct-acting and double-break structure, operation flexible, conveniently manual operation inspect.
3. The contactor connection terminal has insulating boot , very safe.
4. The contactor can be install by screw, also can install in the bus bar.
Working condition:
1. The altitude of installation place can not exceed 2000mm
2. Air temperature around can not exceed 40℃, not lower than -5℃.
3. Humidity: 50% at 40℃.,90% at 20℃.
4. Install condition: can not incline 5℃ to vertical plane.
5. Class of pollution :3 degree
6. No impact and shake.
Main technical data:
Model |
CJ19-32 |
||||||
Conventional thermal current (A) |
32 |
||||||
Rated current(A) AC-6b A |
25 |
||||||
Controlled capacitor kvar |
230V-250V |
9 |
|||||
400V-450V |
15 |
||||||
690V |
15 |
||||||
Capability to restrain surge |
20In |
||||||
Coil |
Working voltage Us 50Hz V |
220,380 according to the customer’s requirement |
|||||
Operating range |
0.85-1.1 Us |
||||||
Consumed power VA |
Start |
115 |
|||||
holding |
11 |
||||||
Electrical endurance 104 times |
10 |
||||||
Mechanical life 104 times |
100 |
||||||
The max operation frequency times/h |
300 |
||||||
Insulation voltage (V) |
500V |
||||||
Auxiliary contact |
Convention thermal current (A) |
10 |
|||||
Electrical endurance 104 times |
AC-15 |
360VA |
12 |
||||
DC-13 |
33W |
12 |
|||||
The smallest load to connect |
6V x 10 mA |
||||||
Current-limited resistor input time (ms) |
7-9 |
Overall and installation size
CJ19 Contactor |
A MAX |
B MAX |
C MAX |
CONTROL CAPACITY |
CJ19-25 |
47 |
80 |
124 |
SUITABLE CAPACITOR≤ 12kvar≤ |
CJ19-32 |
58 |
90 |
132 |
SUITABLE CAPACITOR≤ 15kvar≤ |
CJ19-43 |
58 |
90 |
136 |
SUITABLE CAPACITOR≤ 20kvar≤ |
CJ19-63 |
79 |
132 |
150 |
SUITABLE CAPACITOR≤ 12kvar≤ |
CJ19-95 |
87 |
132 |
160 |
SUITABLE CAPACITOR≤ 30kvar≤ |
CJ19-115 |
121 |
220 |
156 |
SUITABLE CAPACITOR≤ 60kvar≤ |
CJ19-150 |
121 |
220 |
156 |
SUITABLE CAPACITOR≤ 80kvar≤ |
CJ19-170 |
121 |
220 |
156 |
SUITABLE CAPACITOR≤90kvar≤ |
If you have any enquiry about quotation or cooperation,please free to email us at niki@zhiyue.com or use the following enquiry form,Our sales representative will contact you within 24 hous.thank you for your interest in our products.