Name:Main circuit,Rated working voltage (Ue),Unit:kV,Value:3.6;
Name:Main circuit,Rated working current (Ie)Unit:A,Value:400;
Name:Main circuit,Rated frequency (fr),Unit:Hz,Value:50
Name:Main circuit,Rated working voltage (Ue),Unit:kV,Value:12;
Name:Main circuit,Rated working current (Ie)Unit:A,Value:400,630;
Name:Main circuit,Rated frequency (fr),Unit:Hz,Value:50
Name:Main circuit,Rated working voltage (Ue),Unit:kV,Value:7.2/12;
Name:Main circuit,Rated working current (Ie)Unit:A,Value:630;
Name:Main circuit,Rated frequency (fr),Unit:Hz,Value:50
Name:Main circuit,Rated working voltage (Ue),Unit:kV,Value:12;
Name:Main circuit,Rated working current (Ie)Unit:A,Value:800,1000,1250;
Name:Main circuit,Rated frequency (fr),Unit:Hz,Value:50
Name:Main circuit,Rated working voltage (Ue),Unit:kV,Value:7.2/12;
Name:Main circuit,Rated working current (Ie)Unit:A,Value:400,630;
Name:Main circuit,Rated frequency (fr),Unit:Hz,Value:50
Name:Main circuit,Rated working voltage (Ue),Unit:kV,Value:12;
Name:Main circuit,Rated working current (Ie)Unit:A,Value:400,630;
Name:Main circuit,Rated frequency (fr),Unit:Hz,Value:50
Name:Main circuit,Rated working voltage (Ue),Unit:kV,Value:24;
Name:Main circuit,Rated working current (Ie)Unit:A,Value:400,630;
Name:Main circuit,Rated frequency (fr),Unit:Hz,Value:50
Name:Main circuit,Rated working voltage (Ue),Unit:kV,Value:24;
Name:Main circuit,Rated working current (Ie)Unit:A,Value:630;
Name:Main circuit,Rated frequency (fr),Unit:Hz,Value:50
Name:Main circuit,Rated working voltage (Ue),Unit:kV,Value:40.5;
Name:Main circuit,Rated working current (Ie)Unit:A,Value:250, 400, 630;
Name:Main circuit,Rated frequency (fr),Unit:Hz,Value:50
Rated working voltage (Ue):40.5KV
Rated working current (Ie):250A,400A, 630A
Rated frequency (fr):50Hz
Rated working voltage (Ue):40.5KV
Rated working current (Ie):630A/1250A
Rated frequency (fr):50Hz
Rated working voltage (Ue):7.2kV/12kV
Rated working current (Ie):400A,630A
Rated frequency (fr):50Hz
This series of controller is suitable for the automatic adjustment device of capacitor compensation device in low-voltage distribution system,with high-performance microprocessor as the core device,sampling physical quantity for power factor and reactive power in two optional modes,fundamental wave sampling against high harmonics of the grid,so that the power factor of the grid is stable in the range specified by the user,which can be widely applied to different grid conditions.
The static var generator (ZYSVG) detects the load current in real time through an external current transformer (CT), analyzes the reactive power content of the load current through internal DSP calculations, and then controls the PWM signal generator to send a control signal according to the set value.
1. the frequency of system
2. rated current
3. Rated reactance rates.
4. rated capacity
5. the style of installation(horizontal/ overstow)
。Rated voltage: 230VAC, 400VAC, 525VAC, 690VAC, 750VAC, 1050VAC, 1200VAC
。Rated output: 1-60 KVAR
。Rated frequency: 50Hz or 60Hz
。Capacitance Tolerance: -5% - +10%
。Tangent of the loss angle: With the power frequency rated voltage,
。Rated voltage: 0.23kv, 0.4kv, 0.415kv, 0.45kv, 0.525kv and so on.
。Rated output: 1-30kvar.
。Capacitance tolerance: -5% - 10%.
。Tangent of the loss angle: smaller than 0.1%.
。Between terminals withstand voltage:2.15 times rated voltage for 5 seconds.
Use cylinder aluminium tin sealed.
Use microcrystalline wax and healthy dielectric oil as the impregnant.
It has built-in pressure separation device and discharge resistor.
Use dielectric metallized plypropylene film as medium.
With the development of reactive compensation technology, as for three-phase unbalanced load,
to conduct the split phase compensation of the reactive power by applying the way of respective three-phase switching of capacitor,
so as to improve the accuracy of the compensation and optimize electricity-saving result.
In order to do so, our company has developed split phase compensation shunt capacitor.
Comprehensive pole-mounted capacitor bank solutions can be tailored to meet customer application needs. This customized bank package offers overall system improvements such as improved power factor, system capacity release, loss reduction, voltage stability, improved power flow and cost savings.
Comprehensive pole-mounted capacitor bank solutions can be tailored to meet customer application needs.
The Zhiyue’s new generation ZCS capacitor switch is a special electrical field design on vacuum interrupter and switch body insulation for switching capacitive current.
The Zhiyue overhead transformer may be used alone for the supply of a single phase load or as one of three units in a bank for the supply of a three phase load.
Power factor correction capacitors are square type capacitors that are used to improve the power factor of electrical systems.
。Rated Voltage: 230V, 400V, 450V, 480V, 525V, 690V, 750V, 1200V, other custom voltages available;
。Rated Capacity: 1kvar to 60kvar for 0.4~0.69kV, other custom capacities available;
。Rated Frequency: 50Hz or 60Hz;
。Capacity Tolerance: -5% to +10%;