。Rated Voltage Level (kV): 0.23, 0.25, 0.4, 0.45, 0.48, 0.525;
。Rated Capacity (kvar): 1~50;
。1~10kvar: Single-ended terminal;
。12.5~30kvar: Screw terminal;
。35~50kvar: Delta terminal(<400V);Screw terminal(>400V)
。Capacitance Deviation (uF): -5% to +10%;
。Loss Tangent (tanφ): <0.1% (at Un, 50Hz, 20℃);
With the development of reactive power compensation technology, for three-phase unbalanced loads, the method of separately switching capacitors for each phase can be employed to compensate for the reactive power of each phase.
This approach enhances compensation accuracy and improves energy-saving effects. To achieve this, our company has developed a parallel capacitor configuration that enables both phase-by-phase and inter-phase compensation, facilitating the selective switching of capacitors for different phases.
These capacitors possess a higher ability to withstand currents and are connected in series with reactors to suppress harmonic current amplification and prevent resonance. Additionally, this product functions as a reactive power compensator.
。Rated Voltage Levels (kV): 0.45, 0.48, 0.525.
。Rated Capacity (kvar): 15~60.
。Capacitance Deviation (μF): 0~+3%.
。Dissipation Factor (tanδ): ≤0.1% (at Un, 50Hz, 20℃).
。Rated Voltage Levels (kV): 0.33, 0.45, 0.48, 0.525, 0.80
。Rated Capacity (kVar): 15~100
。Capacitance Tolerance (μF): 0~+3%
。Loss Tangent (tanδ): ≤0.1% (at Un 50Hz 20℃)
。High capacity, high bit characteristics
。Fully water-cooled, semi-water-cooled
。Environmentally friendly medium
。Pressure protection
。Altitude: <2000m
。Ambient Temperature: 5℃~45℃
。Relative Humidity: ≤85%
。Capacity Deviation: ±5%
。Rated Voltage: 1-3.4kV
The role of DZMJ DC filter capacitors is to provide filtering and voltage support on the direct current (DC) side of the power supply.
。Large capacity: 300~5000μF
。High current: Maximum current reaches 2500A
。High voltage: 800~1800VDC
。Cooling method: Full water cooling or semi-water cooling
。 Non-toxic impregnating agent
。 Equipped with pressure protection relay
In power supplies where thyristors are used as switches, they are connected in series with resistors to form an RC absorption protection circuit. This circuit prevents voltage spikes during thyristor turn-off, thereby protecting the thyristors.
。Altitude Environment: <2000m
。Temperature Range: -25 to +40°C
。Humidity Level: <85%
。Protection Rating: IP00 for indoor installation
1 Power transformer 10kv and 35kv low-loss series
2 low loss, low noise, high reliability
3 Iron core is made of cold-rolled silicon-steel
4 Have good ability withstand short-circuit
5 The oil tank is bell type with the structure of full folding plate type,
power distribution transformer
1.Standards: IEC60076
2.Rated voltage:10kV
3.Low wastage,low noise
4.Easy installation
。Altitude: ≤1, 000m
。Highest ambient temperature: +40℃
。Highest annual average temperature: +20℃
。Highest monthly average temperature: +30℃
。Lowest temperature: -25℃
。Standard: IEC60076, GB1094-1996; JB/T10088-2004; GB/T6451-2008; EQV
。Voltage Grade: 6KV to 35KV
。 Voltage Regulation Mode: No-load tap changing or On-load tap changing
。Tapping Range: ±5%, ±2×2.5%, ±4×2.5% or others
。Frequency: 50Hz; 60Hz
。Rated Capacity (KVA): 10~2500 KVA
。Vector Group: Yyn0 or Dyn11
。Impedance Voltage (%): 4%, 4.5%
。Rated voltage: H. V: 11, 10.5, 10, 6.3, 6KV (or customized)
。L. V.: 0.4, 0.69KV (or customized)
。Voltage class: 6-35KV
。Model of voltage regulation: Off-excitation or on-load tap changer
。Tapping range: 5%, 2x2.5%,
。Power Capacity: 10-4000kVA
。Frequency: 50Hz or 60HZ
Altitude: ≤1, 000m
Highest ambient temperature: +40℃
Highest annual average temperature: +20℃
Highest monthly average temperature: +30℃
Lowest temperature: -25℃
6. Phase No.: Single phase or three phase
7. Vector Group: Yyn0 or Dyn11
8. Impedance voltage: 4~8%
9. Service condition: 100% relative humidity, ambient temperature not more than 40oC or according to customers' requirements
10. Type of cooling: AN or AF
2.1 Temperature condition: -5°C~40°C;the average value within 24h shall not exceed+35°C(special situation excluded);
2.2 Altitude:≤2000m;
2.3 Pollution grade: Grade 3;
2.4 Air conditions:
At mounting site, relative humidity not exceed 50% at the max temperature of +40°C,
higher relative humidity is allowable under lower temperature,
RH could be 90% at +20°C, special measures should be taken to occurrence of dews;
The products conform with IEC60947-1,IEC60947-2 standards.
1.Installation way: foundation installation;
2.Operating mechanism: spring operating mechanism and electromagnetic operating mechanism;
3.Pole material: rubber silicone, ceramic;
4.Application: outdoor 33kV substation, power plant.
5.Current transformer: internal installation, external installation.
is applied for breaking, on Or off of load current in AC three-phase power system of rated 10-12kV with 50/60Hz,
it owns functions of overload and short protection, fast breaking protection, time lapse delay and automatic reclosing ,
it can also be equipped with arrester Or disconnecting (circuit breaker and disconnecting switch combination,
hereinafter called combination intelligent circuit breakers) according to customer' s requirement.
for a period of 12 KV, rated voltage of the three-phase ac 50 HZ outdoor power distribution system.
It uses a vacuum arcing and SF6 gas as insulating medium,
is ZW20-12 type vacuum circuit breaker of the improvement of products.
Cabinet adopted the introduction of Japanese Toshiba VSP5 gas seal technology, explosion-proof, insulating structure
1.Ambient temperature: -35°C ~ +45°C;
2.Altitude: ≤1000m;
3.Wind speed ≤ 35m/s;
4.Earthquake intensity: ≤8 level;
5.Filthy level: IV;
1.Installation way: pole mounted;
2.Operating mechanism: spring operating mechanism and permanent magnetic operating mechanism;
3.Pole type: integrated pole;
4.Application: outdoor 24kV substation, power plant.
5.Operation type: manual, electric, remote control.
1. The altitude: under1000M;
2. The ambient temperature: -25°C-+40°C;
3. The relative humidity of air monthly≤90%, daily≤95%;
4. The wind pressu re:≤7000PA(with speed 34m/s);
5. Ampitude: Earthquake degree 8;
1. Altitude:≤1000m;
2. 2. Ambient temperature: -25°C~+40 °C;
3. Relative humidity: daily average≤95%, monthly average ≤90%;
4. Earthquake intensity:≤8 degree;
5. Applicable occasions should free from inflammables, explosives Corrosives and severe vibration